USAfixTM - Repair Guide (RG) - Master Email RG
- Replace the Solution Nozzle
 Level of Difficulty - Medium  Estimated Completion Time - 15 minutes
NILFISK - AQUACLEAN 18

Tools Required
Tool 
Crescent wrench
Pliers-needle nose

Parts Required
PartDescriptionPriceAvailablePurchase
172-1326 Nozzle $85.24 Back Order Qty:


Step Procedure & Parts & Tools
1 Disconnect both hoses. Remove the recovery tank lid.

2 Remove the recovery tank.

3 Tip machine back. Using pliers and a crescent wrench hold the “T” with the pliers and twist the spray nozzle off by using a crescent wrench.
Crescent wrench
Pliers-needle nose

4 If nozzle cannot be cleaned out, or if the tip is damaged replace. Reverse steps to install

PartDescriptionPriceQty
172-1326 Nozzle $85.24 Qty: